1
Service error: -
Error tree: Implementation of second self test
Service error: -
Unit type: iCombi Classic
V03 · 04/2021 · RTS/Awei · en-GB
After changing the circuit board, a self-test must be carried out.
Gas units: After the self-test has been carried out, a flue gas analysis
must be carried out.
Select the icon with the two gear wheels
3 icons and a "back arrow" button appear on the screen
A symbol with 3 dashes appears on the screen under the current time in the right corner of the display
Select this symbol by pressing the button on the right side of the screen with your finger
Push the GN container into the middle of the cooking cabinet at the level of the fan wheels and switch on the unit.
Then select the icon with the "two overlapping squares".
On the next screen, select the icon with the "lock and spanner"
You will be asked to enter the service password. Use the control knob for the input.
Enter the service password "TECLEVEL"
Confirm the entry with the green tick
Basic requirements: The cooking cabinet sensor B1 (<40°C). Control
temperature sensor B2 (<65 °C) and climate sensor B4 (<40°) For
adequate cooling of the components, it is recommended that the
steam generator is rinsed to enable sufficient cooling of the
components.
Now select the icon with the "two overlapping squares" in the lower left corner of the screen
Select "Basic Settings"
A scroll menu appears in which you can scroll down with the control knob and mark/select the menu item "Self Test"
Use the arrow keys to select "enabled" in the line below the scroll menu
Now press the on/off button. A blue progress bar appears on the screen. Keep the on/off button pressed at least until the blue bar is completely filled
and the unit switches itself off with the display "Goodbye!".
The self-test starts automatically the next time that you press the on/off switch and the unit is switched on.
To start the self-test, press the "START" button