Service error: -
Error tree: CPU board (A11)
Service error: -
Unit type: iCombi Pro
V03 · 04/2021 · RTS/Awei · en-GB
All unit-specific data is on the board as well as on the EEPROM card. The operator's manual is only on the board and the HACCP data is available on both
the EEPROM card and the board.
Therefore, a software update must be carried out after the board has been replaced.
Insert the SD card into the new board.
Install the new CPU board iCombi Pro (A11) 42.00.251
Switch off the unit and disconnect it from the power supply
Dismantle the old CPU board iCombi Pro (A11);
Remove the SD card for use with the new board
Changing electronics
(Faulty circuit board)
Reconnect the unit to the power supply and switch it on again. Wait until the verification mark appears and confirm with the green tick.
Unit boots by itself.
Connect the USB stick with the latest software to the unit.
Software update to the latest
version is automatically carried out (blue screen with the inscription "Software Installer" and the progress bar appears.
The USB stick for the software update can be removed as soon as the screen display changes to the basic screen after installation (it is not necessary to
restart the unit).