1
Service error: 42.5
Service error 42.5
Error tree: Solenoid valve clima conditioning Y5/Y15 does not open
Service error: 42.5
Unit type: iCombi
V01 · 05/2021 · RTS/Shof · en-GB
1
Check the solenoid valve Y5/Y15 for dirt or blockage preventing
opening.
Note on the iCareSystem module test:
Select service level (TECLEVEL) -> "CleanJet & Care"
launcher -> "Module test" tab -> "Module test
iCareSystem".
If the solenoid valve Y5/15 does not open, no fresh air can be supplied,
meaning that the steam saturation builds up more and more.
Remove the side panel of the unit.
Problem solved? EndYes
No
Disconnect the connector from contact X11 of the I/O board and check
the output voltage with a multimeter.
Is 12 V measured
when Y5/Y15 is triggered, e.g. in the event of
steam?
Replace the I/O board.
End
No
Connect the connector on contact X11 on the I/O board again.
Yes
Disconnect the connector on solenoid valve Y5/Y15. Check the input voltage
with a multimeter.

Other manuals for Rational iCombi Classic

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational iCombi Classic and is the answer not in the manual?

Rational iCombi Classic Specifications

General IconGeneral
ModeliCombi Classic
MaterialStainless steel
Cooking ModesConvection, Steam
Temperature Range30°C to 300°C
Capacity10, 20
Power Supply400V 3-phase
Power ConsumptionVaries by model
DimensionsVaries by model
WeightVaries by model
Cooking Levels10, 20, or 40

Related product manuals