EasyManua.ls Logo

Rational iCombi Classic

Rational iCombi Classic
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
Service error: 33.3
Error tree: Automatic ignition controller
Service error: 33.3
Unit type: iCombi
V01 · 05/2021 · RTS/Shof · en-GB
Error in the gas combustion system
"Blocking error" after the error has been resolved, automatic reset
Service 33.3
Mains frequency errorGas error 45
Service error 33.3
Switch the unit to the gas type declared on the
nameplate.
Note: Repeat flue gas check required!
Does the connected gas type match what is indicated
on the nameplate?
No
Yes
Mains frequency outside the valid range
of 40...70 Hz?
Check the mains frequency, switch the unit off
and on again.
Yes

Other manuals for Rational iCombi Classic

Related product manuals