Service error: 42.3
Service error 42.3
Error tree: Steaming solenoid valve Y3 does not open
Service error: 42.3
Unit type: iCombi
V01 · 05/2021 · RTS/Shof · en-GB
Check that the latest unit software is installed on the
unit.
1
Check the water feed and the moistening
nozzle for calcification.
Check the steaming solenoid valve Y3 in the
function test under service level (TECLEVEL).
Does the CDS sensor count up
when the Y3 is activated?
Run the iCareSytem.
Once complete, return to
the start screen.
End
Yes
Note on the iCareSystem module test:
Select service level (TECLEVEL) -> "CleanJet & Care"
launcher -> "Module test" tab -> "Module test
iCareSystem".
Replace the solenoid valve
block.
Is water flowing through the
moistening nozzle? (look in the
cabinet)
Yes
No
Problem solved? EndYes
Remove the side panel of the unit.
No
Check the connectors on the solenoid valve
block and on the I/O board to ensure that
they are connected correctly to the contacts.
No

Other manuals for Rational iCombi Classic

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational iCombi Classic and is the answer not in the manual?

Rational iCombi Classic Specifications

General IconGeneral
ModeliCombi Classic
MaterialStainless steel
Cooking ModesConvection, Steam
Temperature Range30°C to 300°C
Capacity10, 20
Power Supply400V 3-phase
Power ConsumptionVaries by model
DimensionsVaries by model
WeightVaries by model
Cooking Levels10, 20, or 40

Related product manuals