EasyManua.ls Logo

Rauch AXIS-M 20.2 EMC - Page 208

Rauch AXIS-M 20.2 EMC
236 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance and repair C
188
AXIS
AXIS 50.2
Adjusting AXIS 50.2 D:
The metering slide is in the position of step 2 (lightly pressed against the pin).
3. Loosen the fixing screws on the scale of the lower scale arc.
Figure 24: Adjustment scale of metering slide
4. Adjust the scale in such a way that the scale value 85 lies exactly under the
pointer element. Screw the scale back on.
5. Repeat working steps 1 - 2 and 7 - 8 for the right metering slide.
6. Reattach the return spring and the hydraulic cylinders.
NOTICE
Both metering slides must open evenly and to the same extent. Therefore, al-
ways check both metering slides.
NOTICE
After scale correction with electronic slide actuators, a correction of the slide
testing points in the operating unit is necessary.
Please observe the operator’s manual for the operating unit.