Maintenance and repair
189
C
AXIS 50.2
Adjusting AXIS 50.2 W:
The metering slide is in the position of working step 2.
7. Loosen the fixing screws of the scale arc.
Figure 25: Scale fixing screws
8. Adjust the scale in such a way that the scale value 85 lies exactly under the
pointer element. Screw the scale back on.
Figure 26: Metering slide pointer on position 85
9. Repeat working steps 1 - 4 for the right metering slide.
10. Reconnect the actuator to the metering slide.
NOTICE
Both metering slides must open evenly and to the same extent. Therefore, al-
ways check both metering slides.
After scale correction with electronic slide actuators, a correction of the slide
testing points in the operating unit is necessary.
Please observe the operator’s manual for the operating unit.