Use and maintenance manual Touch Radio Hydro
Pag.42
Rev.0 18/05/2021
EN
Warning Pop -Up
Anomaly Description
RDS SYSTEM REGULATION
REQUEST
(only if the RDS system is
installed)
It shows that the testing procedure and initial parameter calibration have been
completed incorrectly.
This indication, however, does not block the stove.
FLOW METER FAILURE
(only if the RDS system is
installed)
It shows a failure of the air ow meter and the stove switches to minimum ca-
pacity disabling the RDS system.
SERVICE REQUEST
The threshold value of set work hours has been reached. The symbol
displayed remains active throughout the work phase. Non-routine maintenance
is required on the stove.
Signalling Reason Solution
CLEAN THE GRATE
(only if the RDS sys-
tem is installed)
The door and the ash box are not
closed correctly
Make sure they are closed properly.
Poor combustion in grate.
Switch o󰀨 the stove, clean the brazier and check the cleanliness of
the support bench, clean the tube bundle by activating the turbolators
and adjust the combustion through pellet/air settings.
Presence of foreign body in air in-
take tube.
Check if present and remove foreign body
The air ow meter may be dirty. Clean the ow meter with the stove in “Switched o󰀨” state
Contact the Support Service
📌The appearance of the “SET RDS” message indicates that the initial parameter testing and calibration procedure was not
carried out correctly. This indication does not imply blocking the stove.
ADJUST
RDS
SYSTEM