12.13Scannerset-upmenuoptions
TheScannerSet-upmenuenablesyoutoconguretheperformanceandbehaviorofyourradarscanner.
FunctionDescriptionOptions
TimedTransmitSet-up
Thismenuitemcontainsasub-menuthatenablesyoutoadjustthetimedtransmit
options:
TimedTransmit
TransmitPeriod
StandbyPeriod
TimedTransmit
On
Off
TransmitPeriod
10Scans
20Scans
30Scans
StandbyPeriod
3minutes
5minutes
10minutes
15minutes
TuneAdjust
Thismenuitemallowsyoutonetunetheradarscanner’sreceiverformaximum
returnsonthedisplay.RaymarinerecommendsthatthisfunctionissettoAuto.
IfyousetthisfunctiontoManualandadjustthesettingshortlyafterpowering
uptheradarscanner,youshouldadjustitagainapproximately10minutesafter
poweringupthescanner,astherequiredsettingwillchangeafterthemagnetron
haswarmedup.
Man
Auto
Man0%100%
EBLReferenceThemeasurementpointusedforreferencewhenmeasuringdistancesusing
ElectronicBearingLines(EBLs)andrangeringsinthechartapplication.The
optionsareRelativetoshipsheadingorreferencedtothecompassisdegrees
MagneticTrueasselectedinBearingMode.
Relative
Mag-True
SeaClutterCurveThismenuitemallowsyoutoadjusttheSeaClutterradarechoesfromwaves
canmakeitdifculttodetectrealtargets.Theseechoesareknownas“seaclutter”.
Severalfactorscanaffectthelevelofclutteryousee,includingtheweatherand
seaconditions,andthemountingheightoftheradar.Theseacluttercurvesetting
adjuststheradar’ssensitivitytoseaclutter.Thesteepestsettingforthecurveis
1,andthemostshallowsettingis8.
AdjustCurve(1to8)
ScannerSpeedSuperHDopenarrayradarswithsoftwareversion3.23oraboveorHDdigital
radomessupportmultiplescanspeeds:
24RPM
48RPM
ScannerSpeed
24RPM
Autohisoptionautomatically
switchesbetweenthe24RPMand48
RPMscanspeedsasappropriate.
AdvancedSet-upThismenuitemcontainsasub-menuthatenablesyoutoadjustthefollowing
options:
BearingAlignment
DisplayTiming
MainBangSuppression
TunePreset
STCPresetNon-HDDigitalradomesonly
ResetAdvanced
BearingAlignment
-180º179.5º
DisplayTiming
0.415nmselectedrange
MainBangSuppression
On
Off
TunePreset
0255
STCPreset
0100%
ResetAdvanced
Yes
No
Adjustingtheradartunecontrol
Fromtheradarapplication:
1.SelectMenu.
2.SelectScannerSet-up.
3.SelectTuneAdjust.
4.SelectTuneAdjust.
SelectingTuneAdjustwillswitchthefunctionbetweenAuto
andMan.
5.InManualmodeusetheRotaryControltoadjustthelevel,to
obtainthemaximumsignalstrength(indicatedbytheeight-step
horizontalbar).
144
e7/e7D/e95/e97/e125/e127/c95/c97/c125/c127

Table of Contents

Other manuals for Raymarine c95

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raymarine c95 and is the answer not in the manual?

Raymarine c95 Specifications

General IconGeneral
BrandRaymarine
Modelc95
CategoryMarine GPS System
LanguageEnglish

Related product manuals