City Series CV40E-12 | 45
installation
Notes:
1. Liner sections should be continuous without any
joints or seams.
2. Only Flex pipe purchased from Regency
®
may be
used for Flex installations
3. Horizontal vent must be supported every 3 feet.
4. Regency
®
Direct Vent System (Flex) is only
approved for horizontal terminations.
5. Flex system can only be used up to a maximum
continuous vent length of up to 10 feet. If longer
runs are required, rigid pipe must be used.
Horizontal Terminations - Flex Vent 4" x 6-7/8"
These venting systems, in combination with the CV40E/CB40E Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Warnock
Hersey/ Intertek. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination
Locations" section.
Regency
®
Direct Vent (Flex) System Termination Kits include all the parts needed to install the CV40E/CB40E using a exible vent.
FPI Kit # Length Contains:
#946-513 2 Feet 1. 6-7/8” exible outer liner (Kit length)
2. 4” exible inner liner (Kit length)
3. spring spacers
4. thimble
5. AstroCap termination cap
6. screws
7. tube of Mill Pac
8. plated screws
9. S.S. screws #8 x 1-1/2” drill point
#946-515 4 Feet
#946-516 10 Feet