City Series CV40E-12 | 69
installation
Construct the sealed rear enclosure to specified width shown below
and desired height (see unit manual for detailed framing instructions).
2. Locate mounting holes in locations shown below and remove nailing
strips (if already installed). Remove drywall finishing edge from right
and left side of window opening, using supplied right-angle screw-
driver.
3. Attach left and right base panels using 2 screws on each side. Re-
move drywall finishing edge from right and left side of window open-
ing using supplied right-angle screwdriver.
4. Move unit into framed opening at desired height and level unit on all
sides. Connect gas and electrical (see manual).
EXTENDED VIEW PANEL INSTALLATION
Mounting
holes
Enclosure width:
CV40E - 46-3/4"
CV72E - 78"
Attach base panels
Install second stud--8.5" out from rst stud
8.5" from stud center to
stud center
Secure base panels
5. Install a second stud as shown. The distance from first to second
stud should be 8-1/2".
6. Secure base panels in place with 5 screws on each side.
8-1/2"
Extended View Panel Installation