Regenerative discharge
Regenerative discharge routes most of the energy from the pack being discharged back
into the Lead Acid battery powering the Dual PowerLab 8x2. This feature is only
available when the Dual PowerLab 8x2 is powered from a Lead Acid battery.
Regenerative discharge supports up to 40A, 1344W maximum per channel.
Regenerative discharge
Enable/disable regenerative discharge at the Dual PowerLab 8x2 via Smart Power
Management for the supply battery.
Enable/disable regenerative discharge, and set maximum discharge current and
maximum discharge voltage, in the CCS Supply tab. Remember also to set supply
battery low voltage cutoff and maximum output current for charge cycles.
Dual PowerLab 8x2 automatically determines whether it is connected to a Lead Acid
battery or a DC power supply. If it detects a power supply, it switches to internal
discharge (10mA to 10A, 95W maximum).