Specifications:
Dual PowerLab Specifications:
Specifications per channel; Dual PowerLab is a two channel Battery Workstation.
For Battery types: Lithium Polymer (1s to 8s balanced, 1s to 2s unbalanced), Lithium
Ion (1s to 8s balanced, 1s to 2s unbalanced), Lithium Manganese (1s to 8s balanced, 1s
to 2s unbalanced), A123 (LiFePO4) (1s to 8s balanced, 1s to 9s unbalanced), NiCd (1s
to 21s), NiMH (1s to 21s), 6v, 12v, 24v Lead Acid batteries (Flooded, Gel, AGM, SLA)
Pack capacity: 20 mAh to 360Ah.
Input voltage: 10-48VDC, reverse polarity protected. Each channel may be operated
on separate power supplies using 110V/15A isolated circuits for best results.
Additionally both channels may be operated on one power supply provided packs on
each channel are isolated.
Input current: 1A to 40A, software limited
Power conversion: Synchronous DC/DC converter, supports multiple switcher
frequencies of 31.25 kHz, 62.5 kHz, 125 kHz; user selectable by preset, 85% to 93%
efficiency depending on output current
Output battery charge current: Adjustable range 10mA to 40A, limited by 40A input
current*
Output battery discharge current: Internal discharge 10mA to 10A, 95W max
Regenerative discharge 10mA to 40A, 1344W max**
Continuous max output power: 408W @ +12VDC input, 1344W @ +39.53VDC
Cell balancing: Resolution: 78uV (16 bit) for 1s-8s Li or A123 (LiFePO4) balanced
charging
Voltage calibration: Cell voltage measurements are factory calibrated to a standard
traceable to NIST; calibration is to +/- 6 mV
Current calibration: Charge current is factory calibrated on a 4A standard; calibration is
to +/- 1mA
Measurement accuracy:
Voltage resolution: 78uV (16 bit)
Voltage tolerance: +/- 6mV
Charge current: +/- 1%
Capacity added to pack: +/- 1%
Percent capacity (“Fuel”): +/- 5% (with accurate fuel table defined for battery being
charged)
Serial data output: 19.2kbps, 8 bits, 1 start bit, 1 stop bit, no parity
Data integrity: Checksum, CRC checking
Size: 10.24 in. (260mm) L x 5.55 in. (141 mm) W x 3.03 in. (77 mm) H