Page Item Function Note
<2>
-3
Forced Toner
Supply
Operation
Factory use only
Do not use in the field.
Toner Density
Initial Setting
Starts and stops the toner
density sensor’s initial setting.
Indicates the gain data of each
color TD sensor.
Both toner supply reference
values of the TD sensor and the
TD sensor gain value are set
automatically when developer is
replaced.
Do not make a copy with new
developer before the initial
developer setting. Do this
without the toner tank installed.
This mode is required when
new developer is installed or
the TD sensor is replaced.
This mode automatically stops
when completed.
Belt Cleaning Performs the transfer belt
cleaning.
This mode must be performed
after replacing the transfer belt.
Belt cleaning automatically
stops after about 10 seconds.
Service
Tables
SM 4-21 A172/A199