1.9 COMMUNICATION
SC600: Communication error between main control and operation panel
boards
- Definition - [B]
The main CPU cannot communicate with the operation panel CPU
properly.
- Possible causes -
Poor connection between main control board and operation panel
board
Main board defective
Operation panel defective
SC601: Communication error between main control and scanner control
boards
- Definition - [B]
The main CPU cannot communicate with the scanner control CPU
properly.
- Possible causes -
Poor connection between main control board and scanner control
board (optical fiber cable)
Optical fiber cable defective
Main control board defective
Scanner control board defective
DC power supply board defective (no dc 5V input to scanner control
board)
SC602: Communication error between main control and transfer belt
motor drive boards
- Definition - [B]
The main CPU does not receive the response signal from the transfer belt
drive board after 3 tries.
- Possible causes -
Poor connection between main control board and transfer belt drive
board
Main control board defective
Transfer belt drive board defective
A172/A199 6-22 SM