9.2 FUSING TEMPERATURE CONTROL
Each rollers are controlled at the temperature shown in the table below.
Stand-by
During Copying
Normal OHP/Thick Paper
Manual Duplex
(Back Side)
1C 2C, 3C, 4C 1C 2C, 3C, 4C 1C 2C, 3C, 4C
Hot
Roller
Temp.
180 160 170 170 170
Normal:160 Normal:170
Thick
Paper: 170
Thick
Paper: 170
Pressure
Roller
Temp.
120 Hot Roller Temp. - 20 120 120