Page Item Function Note
<3>
-3
Drum Potential
Control Output
Indicates the target and actual
data related to process control.
VD:charge potential
VL: exposed drum potential
VB: development bias
γ
: development gamma
VK: development reference data
<3>
-4
Bk Level DA1
Setting
Displays DA1 settings. Factory use only
Bk Level DA2
Setting
Displays DA2 settings. Factory use only
Max Bk Level
Detection Data
after AGC
Displays DA2* settings. Factory use only
Vref DA3 Setting Displays DA3 settings. Factory use only
Auto
γ
Correction Data
Indicates the correction data
decided in auto
γ
correction.
Indication only
Service
Tables
SM 4-29 A172/A199