Page Item Function Note
<4>
-9
Coin Lock
Connection
Not used. Default: No
Key Card Count
Timing
Not used. Default: Paper Exit
Set User
Code(s)
Enables user code mode. Default: OFF
The key counter shorting
connector should be
disconnected to enable user
code mode.
ADS Priority Not used.
Count Up/Down Selects copy count up or down. Default: UP
A3/DLT Double
Count
Counts twice when an A3 or
11" x 17" copy is made.
Defaults: OFF
Service
Telephone No.
Stores the service center
telephone number. This
telephone number is indicated
on the LCD when a service call
condition occurs or PM is
required.
Entering procedure:
1. Touch 000000000000000
key.
2. Enter numbers by pressing
the number keys. (touch –
to enter a hyphen).
3. Touch 000000000000000
key.
Length Unit
Changes the length unit (mm or
inches) for Shift, Erase, Size
Mag. and Non Standard
Original.
Default: inch (-10/15/17)
mm (-22/26/27/29)
<4>
-10
ROM Version Indicates the ROM reference
number, with suffix, on each
PCB.
System 1: Main control IC1
System 2: Main control IC522
Scanner 1:
Scanner control IC145
Scanner 2:
Scanner control IC144
IPU: IC305
Operation Panel: IC1
Transfer Belt:
Transfer belt motor drive
IC609
FPU: ---
APL: ---
Service
Tables
SM 4-39 A172/A199