5. Place the test pattern on the exposure glass as shown in the illustration.
If the copier is equipped with an optional dual job feeder, put the test
pattern face-up on top of several sheets of white paper of the same size.
Then place all the sheets face-down on the exposure glass.
6. Press the
Scan Start
[C] key.
The γ correction data will be automatically adjusted.
7. Make copies using the C-4 Test chart in letter mode and printed photo
mode.
8. Compare the copies made before the ACC (Auto Color Calibration) and
after the ACC.
[C]