10. Place the test pattern on the exposure glass as shown in the illustration.
If the copier is equipped with an optional dual job feeder, put the test
pattern face-up on top of several sheets of white paper of the same size.
Then place all the sheets face-down on the exposure glass.
11. Press the
Scan Start
[D] key.
The γ correction data will be automatically adjusted.
12. Print out the test page.
13. Compare the printouts made before the ACC (Auto Color Calibration)
and after the ACC.
14. If you want to recall the previous settings, perform steps 6 ~ 8 and in
step 3 press the
Prev. Setting
key [B] instead of the
Yes
key.
15. If the output quality is still not satisfactory, change the value of the γ
correction data for each mode as follows (contone/halftone).
[D]
Replacement
and
Adjustment
SM 5-31 A172/A199