EasyManua.ls Logo

Ricoh A172 - Page 271

Ricoh A172
525 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SC191: Bar code scanning error
- Definition - [B]
The bar code for the machine identification number cannot be detected
when the AGC is performed after the main switch is turned on.
- Possible causes -
The bar code label is dirty.
Scanner mirrors are not in position
SC192: Bar code number is different
- Definition - [B]
The bar code number is not identical to the machine identification number
stored in memory.
- Possible causes -
Wrong machine identification number in memory
Machine identification number is not entered in the new (replaced)
RAM board
RAM board defective
Main control board defective
SC193: IDU connection error
- Definition - [B]
IDU connection cannot be detected.
- Possible Causes -
IDU is disconnected
IDU defective
SC194: IDU detection error
- Definition - [B]
IDU detection error
- Possible Causes -
IDU defective
A172/A199 6-6 SM