SC551: Pressure roller thermistor open
- Definition - [A]
The output of the pressure roller thermistor goes to 5 V, corresponding to
0°C.
- Possible causes -
Pressure roller thermistor open
Main control board defective
Fusing unit not installed
SC552: Pressure roller warm-up error
- Definition - [A]
Pressure roller temperature does not reach the ready temperature within
12 minutes after the main switch is turned on.
- Possible causes -
Pressure roller thermistor not in position
Pressure roller lamp open
Pressure roller thermistor defective
Main control board defective
SC553: Pressure roller overheat
- Definition - [A]
A pressure roller temperature of over 180°C is detected 5 times.
- Possible causes -
Pressure roller thermistor defective
AC drive board defective (triac)
Main control board defective