(i) Message after the test
(a) If the test is successful:
• [Test Successful] appears at the center of the screen.
(b) If the test is unsuccessful:
• [Test Failed] appears at the center of the screen.
• Error information appears at the lower left-hand corner of the screen.
Remarks: Error information
Error register Register address is displayed.
Error index Index for the register where an error occurred is displayed.
Check data Value set in the register is displayed.
Error data Read value is displayed.
(ii) Processing after the test
(a) If the test is successful:
•
Test mode: The system executes the next test.
•
Continuous mode: The system repeats the same test.
•
Execution mode: The system displays [Menu].
You must press [Menu] to return to the menu screen.
(b) If the test is unsuccessful:
•
The system displays the error message and [Menu].
You must press [Menu] to return to the menu screen.
Menu
VGA Register Test
Test Count :
4444
4444
ERROR REGISTER :
4444
ERROR INDEX :
4444
ERROR DATA :
4444
CHECK DATA :
4444
Test result message
If the test is a success, [Test successful] appears.
If it is not, [Test Failed] appears.
Error information
[Menu] key.
You must press this key to return
to the menu screen.
Trouble -
shooting
SM 6-43 A172/A199