BULLETIN NO. SDC206
/
SDC206E-002
PAGE4OF5’
SUBJECT: AUTO COLOR CALIBRATION (ACC) PROCEDURE
1
O/25/96
19.
At this time, “None” will be selected. Click on “None” and select “Modem” or “Parallel Port”,
(depending on which port the densitometer is connected to).
20.
Click “Start” and follow the directions in the “Status” box on the computer screen and the LCD
read-out on the densitometer.
21.
22.
23.
24.
After reading all CMYK strips, the status box reads “Measurements Read Successfully”.
Click “Accept”.
Click “Test”. Make sure “Calibrator Test Page” is selected, then click on “Print”.
The system will now generate a comparison page with calibrated
&
non-calibrated images,
25.
select “Remove Calibration”.
This removes any previously stored
the system to accept new calibration.
26.
side by side.
From the “Server” menu
calibration and prepares
Click “Apply Calibration”
if the comparison page calibrated image is acceptable. Otherwise,
manually adjust printer gamma settings or refer to Standard Fiery Print Calibration Targets
provided on page 4.
27.
You may check calibration status by selecting “Calibration Status” from the Server menu.
Refer to the Fiery XJ user guide for more information regarding editing calibration curves.
28.
When you are done, select “Quit” from the File menu.
Standard Fiery Print Calibration Targets:
A list of preliminary target numbers are listed on page 5. These targets may be updated and
re-issued as better results are obtained.