EasyManua.ls Logo

Ricoh A172 - Subject: SC321 WHEN USING FIERY; FIELD COUNTERMEASURE:; PRODUCTION COUNTERMEASURE:; ROM ORDERING PROCEDURE:

Ricoh A172
525 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Savin Corporation Page 1 of 2
Technical Service Operations – P.O. Box 10270, Stamford, Connecticut 06904 --- (203) 967-5000
Field Engineering Bulletin
Digital Color Series
TECHNICAL OPERATIONS
BULLETIN NO: SDC206/E – 013 DATE: 2/20/98
Copy Quality
Model - Product/Serial Numbers
Affected
Modification Schedule
Electrical
SDC206
Mandatory
Mechanical Scheduled Visit
Modification
SDC206/E
Next Call
Safety Information Next PM
Technical Information As Necessary
General Information Install Time __________
SYMPTOM:
Intermittent SC321 codes only during Printer Mode (using Fiery).
CAUSE:
The Transfer Belt Start Signal is interrupted / influenced by electrical noise.
SOLUTION:
The tolerance of the software timing has been improved against electrical noise / interference. This is
accomplished through the following Main Board ROMs:
IC1 = A1725114F
IC2 = A1725115F
IC522 = A1725129F
This “F” version software, which is packaged as a kit (P/N A172ROMF), is available in limited quantities, only
for machines exhibiting the indicated symptom. Complete and fax the form on page 2 of this bulletin to
Technical Services.
Note: The “F” version software has been implemented into production units, however S/N cut-in
information is unavailable at this time.
Subject: SC321 WHEN USING FIERY

Table of Contents

Related product manuals