Savin Corporation Page 1 of 2
Technical Service Operations – P.O. Box 10270, Stamford, Connecticut 06904 --- (203) 967-5000
Field Engineering Bulletin
Digital Color Series
TECHNICAL OPERATIONS
BULLETIN NO: SDC206/E – 013 DATE: 2/20/98
Copy Quality
Model - Product/Serial Numbers
Affected
Modification Schedule
Electrical
SDC206
Mandatory
Mechanical Scheduled Visit
Modification
SDC206/E
Next Call
Safety Information Next PM
Technical Information As Necessary
General Information Install Time __________
SYMPTOM:
Intermittent SC321 codes only during Printer Mode (using Fiery).
CAUSE:
The Transfer Belt Start Signal is interrupted / influenced by electrical noise.
SOLUTION:
The tolerance of the software timing has been improved against electrical noise / interference. This is
accomplished through the following Main Board ROMs:
IC1 = A1725114F
IC2 = A1725115F
IC522 = A1725129F
This “F” version software, which is packaged as a kit (P/N A172ROMF), is available in limited quantities, only
for machines exhibiting the indicated symptom. Complete and fax the form on page 2 of this bulletin to
Technical Services.
Note: The “F” version software has been implemented into production units, however S/N cut-in
information is unavailable at this time.
Subject: SC321 WHEN USING FIERY