No. Item Contents Details
2
Operation
Panel Control
The operation panel control
board has been newly added.
The main control board no longer
controls the operation panel.
—
3
Operation
Panel Self
Diagnostic
Mode
The operation panel self
diagnostics mode has been
newly added.
For easier servicing of the
machine.
Others
1
Drum Drive The drum drive mechanism has
been changed from a series of
gears to a timing belt system.
Banding on copies are reduced.
See 3.3 in section 2 for details.
2
Copier Rear
Frame
The thickness of the rear frame
has changed from 1.6 mm to 2.0
mm
Banding on copies are reduced.
3
Fusing exhaust
ozone filter
This filter has been eliminated. Because the ozone amount has
been decreased due to the new
charge corona unit.
Options
1
DJF (A610) See the DJF section for details.
—
2
15-Bin Sorter
(A322)
See the Sorter section for details.
—
3
Holder
(A702-18)
The color of the exterior covers
has been changed.
—
4
Film Projector
Unit (A718)
See the Film Projector Unit
section for details.
—
A172/A199 2-4 SM