Bit Switches - 3
SM 103 D418
Fax Option
Type 9001
D418
Communication Switch 02 (SP No. 1-104-003)
No Function Comments
This bit is ignored for memory
transmissions or if ECM is being used.
4-7 Not used Do not change the settings.
Communication Switch 03 (SP No. 1-104-004)
No Function Comments
0-7
Maximum number of page
retransmissions in a G3
memory transmission
00 - FF (Hex) times.
This setting is not used if ECM is switched on.
Default setting - 03(H)
Communication Switch 04 - Not used (do not change the settings)
Communication Switch 05 - Not used (do not change the settings)
Communication Switch 06 - Not used (do not change the settings)
Communication Switch 07 - Not used (do not change the settings)
Communication Switch 08 - Not used (do not change the settings)
Communication Switch 09 (SP No. 1-104-010)
No Function Comments
0-7 IP-Fax dial interval setting
Adjusts the interval of I-fax dialing.
The interval of I-fax dialing is calculated with the
following formula.
[Interval time = specified value with this switch x
0.2 ms]