Service Program Mode Tables
SM Appendix 4-3 D062/D063/D065/D066
Appendix:
Service
Program
Mode Tables
Adjusts the distance between front and rear fences. A smaller value shortens the
distance. If the fences are too far apart, skewing may occur in the duplex tray. If
the fences are too close, the paper may be creased in the duplex unit.
[–5 to +5/0/0.1 mm]
1102 Fusing Temperature Adjustment
Adjusts the temperature of the fusing units.
001
Duplex Actual Temperature
[0 to 1 /0/1]
002
Duplex Balance Temp (Center Thermistor)
[-30 to 0/-15/1]
003
Duplex Balance Temp (End Thermistor)
[-30 to 0/-15/1]
1103 Fusing Idling
001
IdlingTime (Normal)
D062/D063: [0 to 300 /0/1sec] *For only TWN [0 to300/8/1sec]
D065: [0 to 300 /26/1sec] *For only TWN [0 to300/28/1sec]
D066: [0 to 300 /160/1sec]
-002
IdlingTime (Low)
D062/D063: [0 to 300 /66/1sec] *For only TWN [0 to300/68/1sec]
D065: [0 to 300 /86/1sec] *For only TWN [0 to300/88/1sec]
D066: [0 to 300 /200/1sec]
003
IdlingTime (LowPower)
D062/D063/D066: [0 to 300 /0/1sec]
D065: [0 to 300 /15/1sec]
004
Japan only
IdlingTime (LowVoltage)
*For only C4c (DOM): [0 to 300 /8/1sec]
005
Japan only