Service Program Mode Tables
SM Appendix 4-21 D062/D063/D065/D066
Appendix:
Service
Program
Mode Tables
does not operate when copying with OHP, index sheets, or thick paper.
If blurring occurs in images at the leading edges of copies, switch
SP2602-001 off (set to "0").
001
ON/OFF Setting
(1st Side)
Turns the PTL lamp on/off during transfer to the front side of
the paper at normal speed. This setting is always off when
thick paper or OHPs are fed.
[0 to 1/1]
0: Off
1: On
The timing can be adjusted with SP2602-002.
002
OFF Timing (1st
Side)
Adjusts the length of the space from the leading edge where
PTL quenching is applied to the front side at normal speed.
For example, if you select +3, then quenching will be done 3
mm from the leading edge on the front side.
[-10 to 20/3/1 mm]
003
ON/OFF Setting
(2nd Side)
Turns the PTL lamp on/off during transfer to the front side of
the paper at normal speed.
[0 to 1/1]
0: Off
1: On
004
OFF Timing (2nd
Side)
Adjusts the length of the space from the leading edge where
PTL quenching is applied to the back side at normal speed.
For example, if you select +3, then quenching will be done 3
mm from the leading edge on the back side.
[-10 to 20/3/1 mm]
2801* TD Sensor Initial Setting
-001
Press the EXECUTE button to do the TD sensor initial setting. This SP mode
controls the voltage applied to the TD sensor to make the TD sensor output
about 3.0 V.
When SP2967 is on, the TD sensor output is set to about 2.5 V.
Note: Execute this SP only after replacing the TD sensor or developer.