SERVICE PROGRAM MODE 1 March, 2000
4-36
SP No. Display
Function
Default Setting
User
Tools
3-070-1
Serial Number
0--
3-070-2
Bank Serial Number
0--
3-070-3
PDTable Serial
Number
0--
3-071 Installation Date 0 - -
3-072
Service Telephone
Number
0--
3-073 Clock - - 1-8
3-074 First Power On Date
Use these to input the
serial numbers
Serial number locations:
Main body: Open front
cover, on the left of the
machine (master eject
box area)
Bank: Rear cover
Paper delivery table: On
the base
Do these at installation if
required. The data is
used in the data printout
mode in the system test.
(SP3-70 and -72 can be
seen in SP1-41 and -
50.)
---
3-090
Manual Idling
Rotation
This determines the
number of drum idling
rotations when the user
has selected Quality
Start with the Quality
Start key.
45 0-90 4-12
3-091-1
Auto Idling 0-4h
0 0-90 4-14
3-091-2
Auto Idling 4-24h
0 0-90 4-14
3-091-3
Auto Idling 24-72h
15 0-90 4-14
3-091-4
Auto Idling 72h-Over
15 0-90 4-14
3-092-1
AutoIdling 0-4h Low
Temp
0 0-90 4-14
3-092-2
Auto Idling 4-24h
Low
0 0-90 4-14
3-092-3
Auto Idling 24-72h
Low
These determine the
number of drum idling
rotations in Auto Quality
Start mode, depending
on the length of time the
machine has been
unused.
3-091: 18 to 28 °C
3-092: Below 18 °C
3-093: Above 28 °C
45 0-90 4-14
3-092-4
Auto Idling 72h-Over
Low
45 0-90 4-14
3-093-1
AutoIdling 0-4h
HighTemp
0 0-90 4-14
3-093-2
Auto Idling 4-24h
High
0 0-90 4-14
3-093-3
Auto Idling 24-72h
High
0 0-90 4-14
3-093-4
AutoIdling 72h-Over
High
15 0-90 4-14