1 March, 2000 SERVICE CALL CODES
4-9
Service
Tables
Code Title Conditions Possible Causes
SC07-51 Wing upper
position sensor
remains off
When the wing guide moves
upwards, the sensor is not
activated for more than 6
seconds after the wing guide
motor on signal is generated.
• Defective sensor
• Defective motor
SC07-52
Wing upper
position sensor
remains on
When the wing guide moves
downwards, the sensor is not de-
activated for more than 6
seconds after the wing guide
motor on signal is generated.
• Defective sensor
• Defective motor
SC07-53
Wing lower
position sensor
remains off
When the wing guide moves
downwards, the sensor is not
activated for more than 6
seconds after the wing guide
motor on signal is generated.
• Defective sensor
• Defective motor
SC07-60 Slider paper
sensor (in the job
separator)
remains on
When the slider moves upwards,
the sensor is not de-activated for
more than 9 seconds after the
slider lift motor on signal is
generated.
• Defective sensor
• Defective motor
• Defective job separator
board
SC07-61
Slider upper limit
sensor remains
off
When the slider moves upwards,
the sensor is not activated for
more than 9 seconds after the
slider lift motor on signal is
generated.
• Defective sensor
• Defective motor
• Defective job separator
board
SC07-62 Slider upper limit
sensor remains
on
When the slider moves
downwards, the sensor is not de-
activated for more than 9
seconds after the slider lift motor
on signal is generated.
• Defective sensor
• Defective motor
• Defective job separator
board
SC07-63
Slider paper
sensor (in the job
separator)
remains off
When the slider moves
downwards, the sensor is not
activated for more than 9
seconds after the slider lift motor
on signal is generated.
• Defective sensor
• Defective motor
• Defective job separator
board
SC07-70
Slider HP sensor
remains on
When the slider moves toward
the delivery table, the sensor is
not de-activated for more than 6
seconds after the job separator
motor on signal is generated.
• Defective sensor
• Defective motor
• Defective job separator
board
SC07-72 Slider position
sensor remains
on when the
slider returns
When the slider returns, the
sensor is not de-activated for
more than 6 seconds after the job
separator motor on signal is
generated.
• Defective sensor
• Defective motor
• Defective job separator
board
SC07-73
Slider HP sensor
remains off when
the slider returns
When the slider returns, the
sensor is not activated for more
than 6 seconds after the job
separator motor on signal is
generated.
• Defective sensor
• Defective motor
• Defective job separator
board