SERVICE CALL CODES 1 March, 2000
4-12
Service
Tables
Code Title Conditions Possible Causes
SC45-12 Upper turn gate
motor overrun -
low
The turn gate unit overruns its
lower limit, and the upper low turn
gate switch turns on.
Upper low turn gate
limit switch
Upper turn gate HP
sensor
Upper turn gate motor
SC45-13
Upper turn gate
motor overrun -
high
The turn gate unit overruns its
upper limit, and the upper high
turn gate switch turns on.
Upper high turn gate
limit switch
Upper turn gate HP
sensor
Upper turn gate motor
SC45-20
Lower side
jogger lock
When the side jogger moves, it
does not return for more than 4
seconds.
When the side jogger moves from
home position, the sensor does
not de-activate for more than 2
seconds.
Lower side jogger HP
sensor
Lower side jogger
motor
SC45-21
Lower end jogger
lock
When the end jogger moves, it
does not return for more than 4
seconds.
When the end jogger moves from
home position, the sensor does
not de-activate for more than 2
seconds.
Lower end jogger HP
sensor
Lower end jogger
motor
SC45-22 Upper side
jogger lock
When the side jogger moves, it
does not return for more than 4
seconds.
When the side jogger moves from
home position, the sensor does
not de-activate for more than 2
seconds.
Upper side jogger HP
sensor
Upper side jogger
motor
SC45-23 Lower end jogger
lock
When the end jogger moves, it
does not return for more than 4
seconds.
When the end jogger moves from
home position, the sensor does
not de-activate for more than 2
seconds.
Upper end jogger HP
sensor
Upper end jogger
motor
SC45-30
Lower turn gate
motor lock
After the turn gate motor
operates for 150 ms, there have
been fewer than 100 encoder
pulses from the motor.
Lower turn gate motor
MPU board
SC45-31 Upper turn gate
motor lock
After the turn gate motor
operates for 150 ms, there have
been fewer than 100 encoder
pulses from the motor.
Upper turn gate motor
MPU board
SC80-00 PC controller
interface signal
error
Signal transmission error in the
interface board
Defective interface
board

Table of Contents

Related product manuals