EasyManua.ls Logo

Ridder FertiMiX-Go! - Even Fertilizer Dosing; Testing the Fertimix

Ridder FertiMiX-Go!
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Please exercise caution when working with acid.
5.6.1 Even fertilizer dosing
Due to differences in viscosity, some fertilizers may flow through the venturi faster
than others. This can cause uneven dosing. This can be prevented by further opening
or closing the needle valves. This ensures that the liquid levels in all dosing channels
are the same and operating at the preset capacity. The fluid level can be read using
the sight glass in the dosing channel.
Figure 5-6: Fertilizer dosing
No. Name No. Name
1 Needle valve 2 Sight glass / flow meter
5.7 Testing the FertiMiX
To test the FertiMiX, you can initiate a short irrigation cycle. Please check the
following:
1. Is water being pumped into and out of mixing tank?
2. Is the system pump working without excessive noise?
3. Are fertilizers (and acid) being dosed? You can check this by looking at the sight
glasses on the dosing channels.
4. Are the EC, pH and flow meters showing realistic values?
5. Are the EC and pH setpoints (target values) being achieved?
6. Is the right amount of water being irrigated?
7. Are there any alarms?
FertiMiX
43

Table of Contents