Contents RIGOL
MSO5000 User Guide XV
Pinch & Stretch .............................................................................. 1-23
Drag ............................................................................................. 1-24
Rectangle Drawing ......................................................................... 1-24
Parameter Setting Method ..................................................................... 1-26
To Use the Kensington Security Lock ...................................................... 1-27
To Use the Built-in Help System ............................................................. 1-28
To View the Option Information and the Option Installation ...................... 1-29
Chapter 2 To Set the Vertical System ................................................ 2-1
To Enable or Disable the Analog Channel ................................................. 2-2
To Adjust the Vertical Scale .................................................................... 2-3
Vertical Expansion ................................................................................. 2-4
To Adjust the Vertical Offset ................................................................... 2-4
Channel Coupling .................................................................................. 2-5
Bandwidth Limit .................................................................................... 2-5
Probe Ratio ........................................................................................... 2-6
Input Impedance ................................................................................... 2-7
Waveform Invert ................................................................................... 2-7
Amplitude Unit ...................................................................................... 2-8
Channel Delay ....................................................................................... 2-8
Offset Cal ............................................................................................. 2-9
Channel Label ...................................................................................... 2-10
Chapter 3 To Set the Horizontal System ........................................... 3-1
To Adjust the Horizontal Time Base ......................................................... 3-2
To Adjust the Horizontal Position ............................................................. 3-3
Delayed Sweep ..................................................................................... 3-4
Chapter 4 To Set the Sample System ................................................ 4-1
Timebase Mode ..................................................................................... 4-2
YT Mode ........................................................................................ 4-2
XY Mode ........................................................................................ 4-2
ROLL Mode .................................................................................... 4-4
Acquisition Mode ................................................................................... 4-5
Normal .......................................................................................... 4-5
Average ......................................................................................... 4-5
Peak .............................................................................................. 4-6
High Resolution .............................................................................. 4-7
Sampling Mode ..................................................................................... 4-7
Sample Rate ......................................................................................... 4-7
LA Sample Rate ..................................................................................... 4-9
Memory Depth ...................................................................................... 4-9
LA Memory Depth ................................................................................. 4-10
Anti-Aliasing ......................................................................................... 4-11
Horizontal Expansion ............................................................................ 4-11
Chapter 5 To Trigger the Oscilloscope ............................................... 5-1
Trigger Source ...................................................................................... 5-2

Table of Contents

Other manuals for Rigol MSO5104

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol MSO5104 and is the answer not in the manual?

Rigol MSO5104 Specifications

General IconGeneral
TypeTabletop
Product type-
Bandwidth100 MHz
Sampling rate500000 MS/s
Channels quantity16 channels
Minimum time base setting (per division)3.5 ns
Display typeLCD
Display diagonal9 \
AC input voltage100 - 240 V
AC input frequency45 - 440 Hz
Power consumption (max)75 W
Non-operating altitude3000 - 15000 m
Storage temperature (T-T)-30 - 70 °C
Operating temperature (T-T)0 - 50 °C
Weight and Dimensions IconWeight and Dimensions
Width367 mm