Measurement Category
Measurement Category
MSO5000 series digital oscilloscopes can make measurements in Measurement
Category I.
Measurement Category Definitions
Measurement category I is for measurements performed on circuits not directly
connected to MAINS. Examples are measurements on circuits not derived from
MAINS, and specially protected (internal) MAINS derived circuits. In the latter case,
transient stresses are variable. Thus, you must know the transient withstand
capability of the equipment.
Measurement category II is for measurements performed on circuits directly
connected to low voltage installation. Examples are measurements on household
appliances, portable tools and similar equipment.
Measurement category III is for measurements performed in the building installation.
Examples are measurements on distribution boards, circuit-breakers, wiring
(including cables, bus-bars, junction boxes, switches and socket-outlets) in the fixed
installation, and equipment for industrial use and some other equipment. For
example, stationary motors with permanent connection to a fixed installation.
Measurement category IV is for measurements performed at the source of a
low-voltage installation. Examples are electricity meters and measurements on
primary overcurrent protection devices and ripple control units.
Ventilation Requirement
This oscilloscope uses a fan to force cooling. Please make sure that the air intake and
exhaust areas are free from obstructions and have free air. When using the
oscilloscope in a bench-top or rack setting, provide at least 10 cm clearance beside,
above and behind the instrument for adequate ventilation.

Table of Contents

Other manuals for Rigol MSO5104

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol MSO5104 and is the answer not in the manual?

Rigol MSO5104 Specifications

General IconGeneral
TypeTabletop
Product type-
Bandwidth100 MHz
Sampling rate500000 MS/s
Channels quantity16 channels
Minimum time base setting (per division)3.5 ns
Display typeLCD
Display diagonal9 \
AC input voltage100 - 240 V
AC input frequency45 - 440 Hz
Power consumption (max)75 W
Non-operating altitude3000 - 15000 m
Storage temperature (T-T)-30 - 70 °C
Operating temperature (T-T)0 - 50 °C
Weight and Dimensions IconWeight and Dimensions
Width367 mm