EasyManuals Logo

Rigol MSO5104 User Manual

Rigol MSO5104
372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
Contents RIGOL
MSO5000 User Guide XVII
Abs .............................................................................................. 6-20
Low Pass ....................................................................................... 6-21
High Pass ...................................................................................... 6-22
Band Pass ..................................................................................... 6-23
Band Stop ..................................................................................... 6-24
AX+B ............................................................................................ 6-25
Math Operation Label ..................................................................... 6-26
Auto Measurement ............................................................................... 6-27
Quick Measurement after AUTO....................................................... 6-27
Measurement Parameter ................................................................. 6-30
Measurement Settings .................................................................... 6-36
Remove the Measurement Result ..................................................... 6-39
Statistical Function ......................................................................... 6-39
All Measurement ............................................................................ 6-40
Cursor Measurement............................................................................. 6-40
Manual Mode ................................................................................. 6-42
Track Mode ................................................................................... 6-46
XY Mode ....................................................................................... 6-48
Measure Mode ............................................................................... 6-50
Chapter 7 Digital Voltmeter (DVM) and Frequency Counter .............. 7-1
Digital Voltmeter (DVM) ......................................................................... 7-2
To Enable or Disable DVM Measurement............................................ 7-2
To Select the Measurement Source ................................................... 7-2
To Select Measurement Mode ........................................................... 7-3
To Set the Limits ............................................................................. 7-3
Frequency Counter ................................................................................ 7-4
To Enable or Disable the Frequency Counter ...................................... 7-4
To Select the Measurement Source ................................................... 7-4
To Select the Measurement Item ...................................................... 7-4
To Set Resolution ............................................................................ 7-5
To Clear Count ................................................................................ 7-5
To Enable or Disable the Statistical Function ...................................... 7-5
Chapter 8 Power Analysis (Option) ................................................... 8-1
Power Quality ....................................................................................... 8-2
Ripple .................................................................................................. 8-4
Chapter 9 Histogram Analysis ........................................................... 9-1
To Enable or Disable the Histogram Function ............................................ 9-2
To Select the Histogram Type ................................................................. 9-2
To Select the Histogram Source .............................................................. 9-3
To Set the Histogram Height ................................................................... 9-3
To Set the Histogram Range ................................................................... 9-3
To Enable or Disable the Statistical Function............................................. 9-3
To Reset ............................................................................................... 9-4
Chapter 10 Digital Channel ............................................................... 10-1

Table of Contents

Other manuals for Rigol MSO5104

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol MSO5104 and is the answer not in the manual?

Rigol MSO5104 Specifications

General IconGeneral
TypeTabletop
Product type-
Bandwidth100 MHz
Sampling rate500000 MS/s
Channels quantity16 channels
Minimum time base setting (per division)3.5 ns
Display typeLCD
Display diagonal9 \
AC input voltage100 - 240 V
AC input frequency45 - 440 Hz
Power consumption (max)75 W
Non-operating altitude3000 - 15000 m
Storage temperature (T-T)-30 - 70 °C
Operating temperature (T-T)0 - 50 °C
Weight and Dimensions IconWeight and Dimensions
Width367 mm