Setting the Agility to comply with EN 50131 requirements
1. AccesstheInstaller programming mode.
2. Fromthe[1]Systemmenuselect[5]toaccessth e Settingsmenu.
3. FromtheSettingsmenuselect[4]toaccesstheStandardoption.
4. SelectEN50131.Onceselected,thefollowingchangeswilloccu rintheAg ilitysoftware:
Report Codes
Feature EN 50131 Compliance
Timers
PhoneLinecutdelay Immediate(0minutes)
EntryDelay 45seconds(maximumallowed)
ACDelay Immediate(0minutes)
JammingTime 0minutes
RXSupervision 2hours
SystemControls
QuickArm SettoNO
FalseCodeTrouble SettoYes
ForcedArming SettoNO
Authorizeinstaller SettoYES
OverrideTrouble SettoNO
RestoreAlarm SettoYES
MandatoryEventLog SettoYES
RestoreTrouble SettoYES
ExitAlarm SettoNO
20MinutesSignal SettoYES
EntryAlarm SettoNO
Attenuation SettoYES