AgilityInstallerManual
Page 4-5
1.2 Controls
TheControlmenucontainsparametersthatcont rolspecificsy s temoperations.
System: Controls
Parameter Default
Basicprogramming
QuickArm
YES
YES:Eliminatestheneedforausercodewhenarming(Fullorpartial)thesystembya
keypador2‐wayremotecontrol.
NO:Avalidusercodeisrequiredforarmingusingakeypadorremotecontrol.
AllowBypass
YES
YES:Permitszonebypassingbyauthorizedsystemusersafterenteringavalidusercode.
NO:ZonebypassingisNOTpermitted.
QuickStatus
YES
YES:Ausercodeisnotrequiredbeforepressingthestatuskey/buttononyourwireless
keypadorbi‐directionalremotecontrol.
NO:Ausercodeisrequiredtoactivatethestatuskey.
FalseCodeTrouble
YES
YES:Afalsecodereportissenttothemonitoringstationafterfivesuccessiveattemptsat
armingordisarminginwhichanincorrectusercodeisentered.Noalarmsoundsatthe
premises,butatroubleindicationappears.Thewirelesskeypadwillbelockedfor30
minutes.
NO:Alocalalarmissoundedatthepremises.
SirenSquawk
YES
YES:Armingordisarmingthesystemusingaremotecontrol,wirelesskeypadorakey‐
switchproducesabriefʺchirpʺandactivatesthestrobeasfollows:
• Onechirpindicatesthesystemisarmed(alsowhenarmingwithakeypad).
• Twochirpsindicatethesystemisdisarmed.
• Four
chirpsindicatethesystemisdisarmedafteranalarm.
NO:Noʺchirpʺisproduced.
AudiblePanic
NO
YES:ThesirensoperatewhenaʺPoliceAlarmʺisinitiatedatthekeypad(ifdefined),the
remotecontrolorwhenapaniczoneisactivated.
NO:NosirenoperationoccursduringaʺPanicAlarm,ʺmakingthealarmtrulyʺsilentʺ
(SilentPanic).
Note:Thesystemalwaystransmitsapanicreporttothemonitoringstation.