AgilityInstallerManual
Page 4-4
System: Timers
Parameter Default Range
RXSupervision
3hours 0‐7hours
Specifieshowoftenthesystemexpectstogetasignalfromthesystemʹstransmitters.Ifa
signalfromazoneisnotreceivedduringthespecifiedtimethezonewillberegardedas
lost,thesystemwillsendareportcodetothemonitoringstation,andthesystemstatus
will
beʺNotReadyʺ.
Notes:0hoursdisablessupervision
Itisrecommendedtosetthesupervisiontimetoaminimumof3hours
TXSupervision
058 0‐255min
Specifieshowoftenthesystemgeneratesasupervisionrequesttoabi‐directionalwireless
device.
Ifanyoftheaccessoriesdoesnotrespondtotherequest,atleastonce,duringtheRX
Supervisiontime,thesystemwillregardtheaccessoryasLost.
Note:Thedevicewillgeneratethesupervisionmessageaccordingtothetimedefined.
Important:TheRXSupervisiontimeshouldbehigherthantheTxSupervisiontimeinordertoeliminate
falselostevent.
RedialWait
30sec 30‐60sec
Thenumberofsecondsbetweenattemptsatredialingthesamephonenumber.
AppliestoboththeMSRetriesandFMRetriesparameters.
Note:UsedforbothPSTNandGSM.
SwingerLimitShutdown
00 0‐15times
Aswingerisarepeatedviolationofthesamezone,oftenresultinginanuisancealarm
andusuallyduetoamalfunction,anenvironmentalproblem,ortheincorrectinstallation
ofadetectororsensor.
Thisparameterspecifiesthenumberofviolationsofthesamezonereportedduringa
singlearmedperiod,
beforethezoneisautomaticallybypassed.
Note:00todisablestheswingershutdown
NoActivity
00 0‐99hours
Determinesthetimelimitforreceptionofsignalsfromsensorsusedtomonitorthe
activityofsick,elderlyordisabledpeople.Ifnosignalisreceivedfromazonedefined
withtheʺNoActivityʺfeatureatleastoncewithinthedefinedtimelimit,a“no‐activity”
alertcanbesendto
FollowMedestination,alocalmessagecanbeheardandareportto
MonitoringStationcanbedefinedtobesend.
Options:0=thisparameterisinactive.