AgilityInstallerManual
Page 4-17
Zones: Parameters
Parameter Default Range
Exit/Entry1
UsedforExit/Entrydoors.ViolatedExit/Entryzonesdonotcauseanintrusion
alarmduringtheExit/EntryDelay.Ifthezoneisnotsecuredbytheendthe
delayexpiresitwilltriggeranintrusionalarm.
Tostartanarmingprocess,thiszoneshouldbesecured.Whensystemisarmed,
thiszone
startstheentrydelaytime.
Exit/Entry2
Sameasabove,exceptthattheExit/Entry2timeperiodapplies.
Exit(Op)/Entry1
UsedforanExit/Entrydoor.ThiszonebehavesasdescribedintheExit/Entry1
parameter,shownabove,exceptthat,iffaulted,thearmingprocessisnot
prevented.Toavoidanintrusionalarm,itmustbesecuredbeforetheexpiration
oftheExitDelayperiod.
Exit(Op)/Entry2
Sameasabove,exceptthattheExit(Op)/Entry2timeperiodapplies.
EntryFollower
Usuallyassignedtomotiondetectorsandtointeriordoorsprotectingthearea
betweentheentrydoorandthesystem.
Thiszone(s)causesanimmediateintrusionalarmwhenviolatedunlessan
Exit/Entryzonewasviolatedfirst.Inthiscase,EntryFollowerzone(s)will
remainbypasseduntiltheendoftheEntryDelay
period.
Intruder(Instant)
Usuallyintendedfornon‐exit/entrydoors,windowprotection,shockdetection,
andmotiondetectors.
Causesanimmediateintrusionalarmifviolatedafterthesystemisarmedor
duringtheExitDelaytimeperiod.
WhenAutoArmandPre‐Warningaredefined,theinstantzonewillbearmedat
theendofthe
Pre‐Warningtimeperiod.
Interior+Exit/Entry1
UsedforExit/Entrydoors,asfollows:
IfthesystemisarmedintheAway(FullArm)mode,thezone(s)
provideadelay(specifiedbyExit/Entry1)allowingentryintoandexit
fromanarmedpremises.
IfthesystemisarmedintheStaymode,thezoneisbypassed.