AgilityInstallerManual
Page 4-19
Zones: Parameters
Parameter Default Range
Fire
Forsmokeorothertypesoffiredetectors.Thisoptioncanalsobeusedfor
manuallytriggeredpanicbuttonsorpullstations(ifpermitted),asfollows:
Ifviolated,itcausesanimmediatefirealarm,firereporttothemonitoring
station.
Panic
Usedforexternalpanicbuttonsandwirelesspanictransmitters.
Ifviolated,animmediatepanicalarmissounded(ifthezonesoundisnot
definedassilentorAudiblePanicsystemcontrolisenabled),regardlessofthe
systemʹsstateandpanicreportissendtothemonitoringstation.Analarm
display
willnotappearonthekeypads.
Special
Forexternalauxiliaryemergencyalertbuttonsandwirelessauxiliaryemergency
transmitters.
Ifviolated,animmediateauxiliaryemergencyalarmissounded,regardlessof
thesystemʹsstateandreportissenttothemonitoringstation.
Tamper
Fortamperdetection.Thiszoneoperatesthesameas24hourszone,butithasa
specialreportingcode.
Water(Flood)
Forfloodorothertypesofwaterdetectors.Thiszoneoperatesthesameas24
hourszone,butithasaspecialfloodreportcode.(SeeAppendixA:ReportCodes)
Gas
ForGas(naturalgas)leakdetector.Thiszoneoperatesthesameas24hours
zone,butithasaspecialgasreportcode.(SeeAppendixA:ReportCodes)
CO
ForCO(CarbonMonoxide)gasdetectors.Thiszoneoperatesthesameas24
hourszone,butithasaspecialCOreportcode.(SeeAppendixA:ReportCodes)
HighTemperature
Fordetectortemperature(hotorcold).Thiszoneoperatesthesameas24hours
zone,butithasaspecialreportcode.(SeeAppendixA:ReportCodes)
LowTemperature
Fordetectortemperature(hotorcold).Thiszoneoperatesthesameas24hours
zone,butithasaspecialreportcode.(SeeAppendixA:ReportCodes)