AgilityInstallerManual
Page 4-36
I/O Expander: Output Parameters
Parameter
Activation/Deactivation
Whentheutilityoutputisfollowingmorethanonepartitionorzone,theinstallercan
choosethelogicoftheUtilityOutputactivationasfollows:
IfthepatternoperationoftheoutputisdefinedasLatchN/OorLatchN/C,th e
activationanddeactivationoftheoutputscanfolloweitheraft e r allthe
Partitions/ZonesorafteranyofthePartitions/Zones.
IfthePatternope rationofth e outputisdefinedasPulseN/OorPulseN/ C,the
activationofthe outputscanfolloweitherafterallthePartitions/Zonesorafterany
ofthePartitions/Zones.Thedeactivationoper a tionfollowsthedefinedtimeperiod.
PulseDurationLength
05sec 01‐90
ThetimethatanoutputdefinedasPulsedN.OorPulsedN.Cwillbeactivated.Atthe
endofthepulsedurationtheoutputreactivatesautomatically.
X‐10Outputs
ThewirelessI/OexpanderenablesthesystemtocontrolX–10devices.TheI/Oexpander
convertstheinformationsentfromtheprogrammableutilityoutputintotheX–10
protocol.UptosixteenX‐10devicescanbeactivated.Thesearerecognizedinthesystemas
outputs5‐20.
I/O Expander: X-10 Outputs
Parameter Default Range
Label
Alabelidentifiestheoutputinthesystem
Type
Refertotheexplanationundertheutilityoutputsection.
Pattern
Refertotheexplanationundertheutilityoutputsection.
PulseLength
05sec 01‐90
Refertotheexplanationundertheutilityoutputsection.