Robertson AP21 and AP22 Autopilots
78 20220596E
connectors facing down. The NI300X is designed to operate in a
location that provides ambient temperatures below +55°C
(+130°F). It is fastened to the panel/bulkhead by the external
mounting brackets.
Note ! The NI300X is not weatherproof, and must be installed in a dry
location!
The NI300X NMEA Interface (expansion) Unit is designed to
handle installations where more NMEA lines have to be tied
into the system. Four NMEA ports are available. An additional
output data-port with DATA/CLOCK signal is capable of
generating heading data in the format used by some radar
displays made by Anritsu and Furuno. This feature is thus
added to the system if a J3000X Junction Unit is installed (J3000X
has no radar Clock/Data output as compared to J300X and
J300X-40).
Configuration for Anritsu or Furuno is selected in the
Installation Menu.
12V out can drive max. 2 IS11 instruments (max 250mA load),
e.g. “Rudder” and “Compass”.