3.3.Environmental andOperatingConditions
Attribute Value
Minimum storage/transit temperature -20 °C [-4 °F]
Maximum storage/transit
temperature
60 °C [140 °F]
Minimum operating temperature 0 °C [32 °F]
Maximum operating temperature
50 °C [122 °F]
1
Humidity (non-condensing)
Palletizing solution:
20-90%RH
PowerPick20 Gripper:
35-85%RH
Food / Clean room / Intrisic Safety (IS) Not compatible
Dust and water
l
Dust: Affect maintenance intervals
l
Water: Not compatible
Other
l
Free from corrosive liquids or gases
l
Free from explosive liquids or gases
1
Speed valuesmight be derated at temperatures above 35 °C (95 °F) depending on program takt time.
Table 3-1: Environmental and operating conditions of the Robotiq Palletizing Solution
CAUTION
Use of the Robotiq Palletizing Solution isnot recommended in presence of chemicals.