Rockwell Automation Publication 2198-RM004C-EN-P - March 2022 15
Chapter 2 Replacement Considerations
Power Specifications This section provides the power specifications for the Kinetix 300 and
Kinetix 5100 servo drives. Table 10
and Table 11 list power specifications and
requirements for the Kinetix 300 servo drives.
2097-V33PR6
120/240V Single-phase LPJ-40SP — 140M-F8E-C32 40 — 140M-F8E-C32
240V Three-phase KTK-R-30 (30 A) 1489-A3C300 140M-F8E-C32 32 1492-SP3D300 140M-F8E-C32
2097-V34PR3
480V Three-phase
KTK-R-10 (10 A) 1489-A3C100
140M-C2E-C10
140MT-C3E-C10
10 1492-SP3D100
140M-C2E-C10
140MT-C3E-C10
2097-V34PR5 KTK-R-10 (10 A) 1489-A3C100
140M-C2E-C10
140MT-C3E-C10
10 1492-SP3D100
140M-C2E-C10
140MT-C3E-C10
2097-V34PR6 KTK-R-20 (20 A) 1489-A3C200
140M-D8E-C20
140MT-D9E-C20
20 1492-SP3D200
140M-D8E-C20
140MT-D9E-C20
Table 8 - Kinetix 300 Drive Fuse and Circuit Breaker (CB) Specifications (Continued)
Drive Cat. No. Drive Voltage Phase
UL Applications IEC (non-UL) Applications
Fuses
(Bussmann)
Miniature CB
Cat. No.
Motor
Protection CB
Cat. No.
DIN gG Fuses
Amps max
Miniature CB
Cat. No.
Motor
Protection CB
Cat. No.
Table 9 - Kinetix 5100 Drive Fuse and Circuit Breaker Selection
Cat. No. Voltage (nom) and Phase
UL/CSA Application IEC (non-UL/CSA) Application
Recommended Fuse Cat.
No.
Recommended Circuit
Breaker Cat. No.
DIN gG Fuses Rating
(amps, max)
Recommended Circuit
Breaker Cat. No.
2198-E1004-ERS
120V/230V, 1 PH KTK-R-15 (15 A) 1489-M2D100 15 1489-M2D100
230V, 3 PH KTK-R-10 (10 A) 1489-M3D100 10 1489-M3D100
2198-E1007-ERS
120V/230V, 1 PH KTK-R-20 (20 A) 1489-M2D200 20 1489-M2D200
230V, 3 PH KTK-R-15 (15 A) 1489-M3D130 15 1489-M3D130
2198-E1015-ERS
120V/230V, 1 PH KTK-R-30 (30 A) 1489-M2D300 30 1489-M2D300
230V, 3 PH KTK-R-25 (25 A) 1489-M3D200 25 1489-M3D200
2198-E1020-ERS
120V/230V, 1 PH LPJ-40SP (40 A) 1489-M2D400 40 1489-M2D400
230V, 3 PH LPJ-35SP (35 A) 1489-M3D300 35 1489-M3D300
2198-E2030-ERS 230V, 3 PH LPJ-50SP (50 A) 1489-M3D350 50 1489-M3D350
2198-E2055-ERS 230V, 3 PH LPJ-70SP (70 A) 1489-M3D600 70 1489-M3D600
2198-E2075-ERS 230V, 3 PH LPJ-80SP (80 A) 140G-G2C3-C70 80 140G-G2C3-C70
2198-E2150-ERS 230V, 3 PH LPJ-125SP (125 A) 140G-G2C3-D12 125 140G-G2C3-D12
2198-E4004-ERS
380…480V AC, 3 PH
KTK-R-10 (10A) 1489-M3D100 10 1489-M3D100
2198-E4007-ERS KTK-R-15 (15A) 1489-M3D100 15 1489-M3D100
2198-E4015-ERS KTK-R-20 (20A) 1489-M3D150 20 1489-M3D150
2198-E4020-ERS KTK-R-25 (25A) 1489-M3D200 25 1489-M3D200
2198-E4030-ERS KTK-R-30 (30A) 1489-M3D300 30 1489-M3D300
2198-E4055-ERS LPJ-35SP (35A) — 35 1489-M3D350
2198-E4075-ERS LPJ-45SP (45A) — 45 140G-G6C3-C45
2198-E4150-ERS LPJ-90SP (90A) — 90 140G-G6C3-C60
Table 10 - Kinetix 300 Drives (Single-phase) Power Specifications
Attribute 2097-V31PR0 2097-V31PR2 2097-V32PR0 2097-V32PR2 2097-V32PR4
AC input voltage
70…132V rms single-phase (120V nom)
80…264V rms single-phase (240V nom)
80…264V rms single-phase (240V nom)
AC input frequency 48…62 Hz
Main AC input current
Rms (nom) 120V input (voltage doubler)
Inrush (0-pk) Max 120V input
Rms (nom) 120/240V input
Inrush (0-pk) max 240V input
9.70 A
1.15 A
5.0 A
1.1 A
15.0 A
1.15 A
8.6 A
1.1
5.0 A
136 A
8.6 A
2.3 A
15.0 A
2.3 A
Integrated AC line filter No No Yes Yes Yes
Continuous output current (rms) 2.0 A 4.0 A 2.0 A 4.0 A 8.0 A