66 Rockwell Automation Publication MOTION-AT007A-EN-P - May 2020
Appendix A Kinetix and PowerFlex Drive Specifications
C104 5
55 – 120.2 64.9
4500 1 1
175
Mersen HSJ175
(3)
–4597.352.5 150
Mersen HSJ150
(3)
C104 6
55 – 120.2 64.9
4600 1 1
175
Mersen HSJ175
(3)
–4597.352.5 150
Mersen HSJ150
(3)
C140 6
75 – 160.3 86.5
4600 1 1
250
Mersen HSJ250
(3)
– 55 120.2 64.9 175
Mersen HSJ175
(3)
C170 6
90 – 194.6 105.1
9200 1 1
350
Mersen HSJ350
(3)
– 75 160.3 86.5 250
Mersen HSJ250
(3)
C205 6
110 – 234.7 126.7
9200 1 1
350
Mersen HSJ350
(3)
– 90 194.6 105.1 350
Mersen HSJ350
(3)
C260 6
132 – 297.7 160.7
9200 1 1
450
Mersen HSJ450
(3)
–110234.7126.7 350
Mersen HSJ350
(3)
(1) Drive input type (position 5 of catalog number) = 1 (AC input with precharge, includes DC terminals) or 4 (DC input with precharge).
(2) See Fuse Certification and Test Data
on page 68 for fuse self-certification and test data for Bussmann 170M and JKS fuses that are recommended for the DC-bus fusing.
(3) A test program was developed to confirm that the HSJ (High Speed J) fuses meet or exceed the requirements set forth by Rockwell Automation for the fuses on the common DC-bus for all
Allen-Bradley® architecture, component, and legacy drives. The criteria for acceptance was:
• 600V AC rectified, 810V DC average, fuses located at (+) and (-) leg. Short circuit test at 65 kA.
• Time constant minimum 3 milliseconds (maximum 15 milliseconds).
• No over-load protection required.
• Let-through must be less than rating of the conductors.
This testing is listed in UL file E2137 Vol2 Sec 31 page 1 and in CSA report 1662646.
Table 61 - 650V DC Input Fuses, Frames 1…6
Drive Cat. No.
20F and 20G
(1)
Frame
Size
HP Rating DC Input Rating
Drive DC Bus
Capacitance
Non-time Delay Fuse
ND HD Amps kW Amps Fuse Cat. No.
Quantity
µF DC+ DC–
D2P1 1
1–1.91.2
110
6
Bussman JKS-6
(2)
11
–0.51.10.72 4
Bussman JKS-4
(2)
D2P1 2
1–1.91.2
705
6
Bussman JKS-6
(2)
11
–11.91.2 6
Bussman JKS-6
(2)
D3P4 1
2–3.02.0
165
6
Bussman JKS-6
(2)
11
–11.91.2 6
Bussman JKS-6
(2)
D3P4 2
2–3.02.0
705
6
Bussman JKS-6
(2)
11
–23.02.0 6
Bussman JKS-6
(2)
D5P0 1
3–4.52.9
280
10
Bussman JKS-10
(2)
11
–23.02.0 6
Bussman JKS-6
(2)
D5P0 2
3–4.52.9
705
10
Bussman JKS-10
(2)
11
–34.52.9 10
Bussman JKS-10
(2)
D8P0 1
5–8.15.3
470
15
Mersen HSJ15
(3)
11
–34.52.9 10
Bussman JKS-10
(2)
D011 1
7.5 – 11.1 7.2
560
20
Mersen HSJ20
(3)
11
–58.15.3 15
Mersen HSJ15
(3)
D011 2
7.5 – 11.1 7.2
705
20
Mersen HSJ20
(3)
11
–7.511.17.2 20
Mersen HSJ20
(3)
D014 1
10 – 14.7 9.6
680
30
Mersen HSJ30
(3)
11
–7.511.17.2 20
Mersen HSJ20
(3)
D014 2
10 – 14.7 9.5
705
30
Mersen HSJ30
(3)
11
–7.511.17.2 20
Mersen HSJ20
(3)
Table 60 - 540V DC Input Fuses, Frames 1…6 (continued)
Drive Cat. No.
20F and 20G
(1)
Frame
Size
kW Rating DC Input Rating
Drive DC Bus
Capacitance
Non-time Delay Fuse
Quantity
Amps Fuse Cat. No.
ND HD Amps kW µF DC+ DC–