Table 31 - 810V DC Input Dimension Cross Reference
PowerFlex 700S (20D…) PowerFlex 755TM Common Bus Inverter (20G1D/E…)
Frame
Size
DC Input
without
Precharge
Catalog
Number
(1)
Enclosure
Type
Width
mm (in.)
Height
mm (in.)
Depth
(2)
mm (in.)
Frame
Size
Common Bus
Inverter
Catalog
Number
(3)
Width
(4)
mm (in.)
Height
IP21/IP54
mm (in.)
Depth
IP21/IP54
mm (in.)
F9
F9
20DK170x
20DK208x
IP21 480 (18.9) 1150 (45.3) 363 (14.3) F8 20G1ynE242… 700 (27.6) 2132 (83.9)/
2291 (90.2)
676 (26.6)/
721 (38.4)
F10 20DK261x IP21 Rittal
IP20 MCC
IP54 Rittal
597 (23.5)
635 (25)
606 (24)
2275 (89.6)
2286 (90)
2404 (94.6)
633 (25)
635 (25)
655 (25.8)
F8 20G1ynE295…
F10 20DK325x IP21 Rittal
IP20 MCC
IP54 Rittal
597 (23.5)
635 (25)
606 (24)
2275 (89.6)
2286 (90)
2404 (94.6)
633 (25)
635 (25)
655 (25.8)
F8 20G1ynE355…
F10
F10
20DK385x
20DK416x
IP21 Rittal
IP20 MCC
IP54 Rittal
597 (23.5)
635 (25)
606 (24)
2275 (89.6)
2286 (90)
2404 (94.6)
633 (25)
635 (25)
655 (25.8)
F8 20G1ynE395…
F10 20DK416x… IP21 Rittal
IP20 MCC
IP54 Rittal
597 (23.5)
635 (25)
606 (24)
2275 (89.6)
2286 (90)
2404 (94.6)
633 (25)
635 (25)
655 (25.8)
F8 20G1ynE435…
F11 20DK460x IP21 Rittal
IP20 MCC
IP54 Rittal
797 (31.4)
889 (35)
806 (31.7)
2275 (89.6)
2286 (90)
2415 (95)
622 (24.5)
635 (25)
655 (25.8)
F11
F11
20DK460x
20DK502x
IP21 Rittal
IP20 MCC
IP54 Rittal
797 (31.4)
889 (35)
806 (31.7)
2275 (89.6)
2286 (90)
2415 (95)
622 (24.5)
635 (25)
655 (25.8)
F8 20G1ynE545…
F11
F11
20DK502x
20DK590x
IP21 Rittal
IP20 MCC
IP54 Rittal
797 (31.4)
889 (35)
806 (31.7)
2275 (89.6)
2286 (90)
2415 (95)
622 (24.5)
635 (25)
655 (25.8)
F9 20G1ynE595… 900 (35.4) 2132 (83.9)/
2291 (90.2)
676 (26.6)/
721 (38.4)
F11 20DK590x IP21 Rittal
IP20 MCC
IP54 Rittal
797 (31.4)
889 (35)
806 (31.7)
2275 (89.6)
2286 (90)
2415 (95)
622 (24.5)
635 (25)
655 (25.8)
F9 20G1ynE690…
F12 20DK650x IP21 Rittal
IP20 MCC
IP54 Rittal
1196 (47)
1270 (50)
1205 (47.4)
2275 (89.6)
2286 (90)
2404 (94.6)
633 (24.9)
635 (25)
655 (25.8)
F12
F12
20DK750x
20DK820x
IP21 Rittal
IP20 MCC
IP54 Rittal
1196 (47)
1270 (50)
1205 (47.4)
2275 (89.6)
2286 (90)
2404 (94.6)
633 (24.9)
635 (25)
655 (25.8)
F9 20G1ynE760…
F12 20DK820x IP21 Rittal
IP20 MCC
IP54 Rittal
1196 (47)
1270 (50)
1205 (47.4)
2275 (89.6)
2286 (90)
2404 (94.6)
633 (24.9)
635 (25)
655 (25.8)
F9 20G1ynE825…
F13 20DK920x IP21 Rittal
IP54 Rittal
1412 (56) 2275 (89.6)
2444 (104.5)
619 (24.4)
662 (26.1)
F9 20G1ynE980…
F13 20DK1K0x IP21 Rittal
IP54 Rittal
1412 (56) 2275 (89.6)
2444 (104.5)
619 (24.4)
662 (26.1)
F10 20G1ynE1K1… 1100 (43.3) 2132 (83.9)/
2291 (90.2)
676 (26.6)/
721 (38.4)
F13 20DK1K1x IP21 Rittal
IP54 Rittal
1412 (56) 2275 (89.6)
2444 (104.5)
619 (24.4)
662 (26.1)
F10 20G1ynE1K2…
F10 20G1ynE1K5…
F14 20DK1K5x... IP21 Rittal
IP54 Rittal
1597 (63)
1597 (63)
2270 (89.4)
2276 (90)
620 (24.5)
662 (26)
F11 20G1ynE2K0… 1500 (59) 2132 (83.9)/
2291 (90.2)
676 (26.6)/
721 (38.4)
F12 20G1ynE2K4… 1700 (66.9) 2132 (83.9)/
2291 (90.2)
676 (26.6)/
721 (38.4)
(1) <x> in catalog number is PowerFlex 700S enclosure type; catalog code A = IP21 Rittal, catalog code B = IP20 MCC, catalog code H = IP54 Rittal.
(2) The dimensions of these PowerFlex 700S units is less than the equivalent PowerFlex 755T unit. Use judgment to ensure there is sufficient space for the migration solution.
(3) <n> In catalog number is PowerFlex 755T enclosure type; catalog code 3= IP21, catalog code 4= IP54.
<
y> in catalog number is PowerFlex 755T input type; catalog code D= 755TM common bus inverter with precharge, E= 755TM common bus inverter without precharge, catalog code F= 755TL,
catalog code G= 755TR.
(4) Width dimension shows total width with power bay and control bay. The control bay is always 300 mm (11.8 in.). One control bay can serve two power bays if configured correctly. Optional wiring
bays add to total width. If optional bays are required, refer to publication 750-TD100
for dimensions and weights.

Table of Contents

Other manuals for Rockwell Automation Allen-Bradley PowerFlex 700S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation Allen-Bradley PowerFlex 700S and is the answer not in the manual?

Rockwell Automation Allen-Bradley PowerFlex 700S Specifications

General IconGeneral
BrandRockwell Automation
ModelAllen-Bradley PowerFlex 700S
CategoryController
LanguageEnglish

Related product manuals