7-4 Frame 11 Installation
Removing Covers
Moving Control Frame
To gain access to the airflow plate and protective covers you must move the
Control Frame out of the way.
Task Description
Loosen the T8 Torx-head screws which secure the Control Frame to the drive enclosure
Swing the Control Frame out and away from the power structure