List of Remote Control Commands R&S SU 4200
6.11 6125.0226.12.01
6.3 List of Remote Control Commands
List of Remote Control Commands\List of Remote Control Commands "Radio".doc
Note: More detailed information is provided by the LAN and
RS-485-GB2PP Interface Control Document, available on demand from
Rohde & Schwarz (Order No. 6144.7497.01).
“TRAP” is not supported in RS-485.
Note: If more than one of the commands TR, SP, PP is sent in sequence,
the first command is acknowledged typically within 200 ms. The following
commands will be acknowledged later. When sending several commands, it
is recommended to send a new command only after the acknowledgement/
command response of the previous command has been received.
6.3.1 GB2PP Commands (LAN/RS-485)
6.3.1.1 Fixed Frequency Commands (FF)
Fixed Freque ncy Commands\ Fixed Fre quency Commands "Radio".doc
Code Command/
parameter
Module Type Unit Step
size
Range Default Description
BL Frequency
Blocking
Range Table
TX GET MHz 8.33
kHz/
25 kHz
112.000 to
155.991
112.000 to
155.975
OFF Table of
forbidden
frequency
ranges; max 8
bands, for
each band a
start and a
stop
frequency is
defined.
FC Filter
Configuration
TX GET – – Record of
filter config
– Provides
current
settings for
external motor
filter.
MD Mode/
Modulation
TX GET,
SET,
TRAP
– 0=AM
2=ACARS
0=AM Provides a way
to get or set the
current
modulation
mode.
SC Enable/
Disable Single
Channel
TX GET – – ON/OFF OFF Provides
information
about the
state of single
channel flag.
SP Channel
Spacing
TX GET,
SET,
TRAP
– – 8.33 kHz/
25 kHz
25 kHz