Local Control (Local Mode) R&S SU 4200
3.37 6125.0226.12.01
Test 1k2 Test for TONE function
Transmitter can be powered up at a test modulation
1.2 kHz and the configured AM modulation depth via
the ENTER key.
Note: TX transmission is switched on as long as the
ENTER key is pressed or until the timeout PTT timer
switches off the transmission.
Note: Only available in ACARS mode.
Test 2k4 Test for TONE function
Transmitter can be powered up at test modulation
2.4 kHz and the configured AM modulation depth via
the ENTER key.
Note: TX transmission is switched on as long as the
ENTER key is pressed or until the timeout PTT timer
switches off the transmission.
Note: Only available in ACARS mode.
3.4.7.4.2 SUPPLY Menu
Meaning
of entries
S u p p l y
L
O
C
B A T T E
R
Y
3
1
.
4
V
D C S E
C
2
7
.
7
V
Fig. 3.30 SUPPLY menu
Display text Values Description
Supply – Menu name
BATTERY +31.4 V Display of battery voltage
DC SEC +27.7 V Display of secondary voltage from power supply unit